日本語 >>
TOP page
Present specialized field
Journal
Presentation
Belonging society
(Last updated : 2024-10-04 11:03:17)
Tatsuhiro Gotanda
Department
Kawasaki University of Medical Welfare ,
Position
Associate Professor
■
Present specialized field
Radiological sciences, Radiological sciences (Key Word:Radiation dosimetry, Radiation protection, Radiochromic film)
■
Journal
1.
2023/11/16
Comparison of sensitivity characteristics between GAFCHROMIC LD-V1 and GAFCHROMIC XR-QA2 in mammographic dosimetry
2.
2023/05/24
Dosimetry using a radiochromic film and a mammography phantom
3.
2023/05/24
Evaluation of factors associated with the effectiveness of radiation protection glasses
4.
2023/01/07
Development of a three-dimensional dose evaluation method for computed tomography
5.
2021/10/20
Three-Dimensional Dosimetry of Mammography Using a Block Cube Breast Phantom and Radiochromic Film
6.
2021/08/02
Use of ultraviolet ray pre-irradiation to improve the accuracy of low-dose measurements of the CT using a Gafchromic RTQA2 film
7.
2021/03/31
The Concept of X-Ray CT Dose Evaluation Method Using Radiochromic Film and Film-Folding Phantom
8.
2019/03
Development of Education and Experiment Assistant System using learning management software in radiological science
9.
2018/12
Ultraviolet ray irradiation duration for the pre-exposure of Gafchromic EBT2
10.
2018/03
Determining optimum wavelength of ultraviolet rays to pre-exposure of non-uniformity error correction in Gafchromic EBT2 films
11.
2017/06
Intensities of incident and transmitted ultraviolet-a rays through gafchromic films
12.
2016/12
Effective Energy Measurement Using Radiochromic Film: Application of a Mobile scanner
13.
2016/12
Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film
14.
2016/07
Results and problems of stepwise education for Interprofessional Education
15.
2016/05
Correction of nonuniformity error of gafchromic EBT2 and EBT3
16.
2015/11
Comparing three UV wavelengths for pre-exposing Gafchromic EBT-2 and EBT-3 films
17.
2015/09
Ultraviolet exposure of Gafchromic XR-RV3 and XR-SP2 films
18.
2015/01
Sonographic Visualization of Fecal Loading in Adults: Comparison With Computed Tomography
19.
2013/03
Evaluation of GAFCHROMIC EBT2 dosimetry for the low dose range using a flat-bed scanner with the reflection mode
20.
2012/01
Sonographic measurement of transient synovitis in children: diagnostic value of joint effusion
21.
2011/06
Evaluation of effective energy using radiochromic film and a step-shaped aluminium filter
22.
2011/04
Improved detection of gastric cancer during screening by additional radiographs as judged necessary by the radiographer
23.
2009/11
High resolution T2 weighted liver MR imaging using functional residual capacity breath-hold with a 1.0-Tesla scanner.
24.
2009/09
Half-Value Layer Measurement: Simple Process Method Using Radiochromic Film
25.
2009/09
Functional residual capacity breath hold for subtraction image of dynamic liver MRI.
26.
2009/03
Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density
27.
2008/12
Dose distribution in pediatric CT head examination using a new phantom with radiochromic film
28.
2008/12
Visualization of Radiation Exposure for Computed Tomography
29.
2007/08
Computed tomography phantom for radiochromic film dosimetry
Display 5 items
Display all(29)
■
Presentation
1.
2024/09/20
Directional dependence of diagnostic radiochromic film (Speech,General)
2.
2024/02/28
Evaluation of the dose distribution using the radichromic film on the surgeon's face including the lens when with and without radiation-protective eyewear (Poster notice,General)
3.
2022/08/31
Effects of Newton rings on radiochromic films used for radiation exposure control (Speech,General)
4.
2022/06/12
Effects of moiré artifacts caused by the scanner light source and the radiochromic film type (Poster notice,General)
5.
2022/06/12
Diagnosis of valvular heart disease by Multi Location Time Enhancement Curve Using Test Injection in CT Examination (Poster notice,General)
6.
2022/06/12
Energy response of Cr-doped Al2O3 Ceramic Plate for Dosimetry in Kilovoltage Range (Poster notice,General)
7.
2022/06/12
Investigation of Exposure Parameters Necessary for the Depiction of Microcalcification Using Magnification Mammography (Poster notice,General)
8.
2022/06/12
Consideration of appropriate attaching position of personal dosimeters in endoscopic retrograde cholangiopancreatography (Poster notice,General)
9.
2022/05/31
DOSIMETRY USING A RADIOCHROMIC FILM AND A MAMMOGRAPHY PHANTOM (Poster notice,General)
10.
2022/05/31
Evaluation of factors associated with the effectiveness of radiation protection glasses (Poster notice,General)
11.
2022/04/15
Evaluation of radiation protection glasses eyes lens shape and lead-equivalent dependent (Speech,General)
12.
2022/03/02
Adaptability of Radiochromic films in mammography (Poster notice,General)
13.
2020/08/29
Three-dimensional dosimetry of mammography using a block cube breast phantom (Speech,General)
14.
2019/02/27
The verification of X-ray mammography dosimetry using radiochromic film (Poster notice,General)
15.
2018/06/03
Evaluation of effective energy distribution of 320-multidetector CT using GAFCHROMIC EBT3 (Poster notice,General)
16.
2018/06/03
Temporal Characterization of the Flat-Bed Scanner Influencing Dosimetry Using Radiochromic Film (Poster notice,General)
17.
2018/06/03
Influence of Image Resolution Property on Aliasing Error of Digital Wiener Spectrum (Poster notice,General)
18.
2018/06/03
Accurately Evaluating Settling Responses of Ionization Chambers Used in Radiation Therapy Depend on the Accelerating Tube (Poster notice,General)
19.
2018/06/03
Size and Shape of Spherical Objects on Full-Field Digital Mammography and Digital Breast Tomosynthesis Images (Poster notice,General)
20.
2018/06/03
Optimal Variable Refocus Flip Angle Control Method and Echo Train Length for Suppressing Exposure to Radio Frequency (Poster notice,General)
21.
2018/06/03
Basic Study of the Imaging Conditions on Tumor Volume Measurement Using 3D-MR Imaging of the Liver While Patient Holds Breath (Poster notice,General)
22.
2018/06/03
Effect of Weight Input in Magnetic Resonance Imaging System on Radio-Frequency-Induced Heating of Metallic Implants (Poster notice,General)
23.
2018/02/28
Development of ultraviolet ray irradiation device for Gafchromic XR-SP2 films (Poster notice,General)
24.
2017/06/11
Influence of scattered radiation on Gafchromic EBT3 (Poster notice,General)
25.
2017/06/11
Ultraviolet Ray Strength for Pre-irradiation in Gafchromic EBT2 (Poster notice,General)
26.
2017/06/11
UV Intensity of Pre-irradiation in Gafchromic XR-RV3 and XR-SP2 (Poster notice,General)
27.
2017/06/11
Basic research on countermeasures against barium sulfate aggregation using a gastric phantom (Poster notice,General)
28.
2017/06/11
Response characteristics of radiochromic film at CT radiation quality (Poster notice,General)
29.
2017/03/01
Effective energy evaluation of 320-multidetector CT using Radiochromic Film (Poster notice,General)
30.
2016/09/01
Temporal characteristic of the scanner influencing dosimetry using radiochromic film (Poster notice,General)
31.
2016/09/01
Ultraviolet ray wavelength in Gafchromic XR-RV3 and XR-SP2 films (Poster notice,General)
32.
2016/09/01
Energy response characteristics of radiochromic film at CT radiation quality (Poster notice,General)
33.
2016/09/01
Optimum wavelength of ultraviolet rays in gafchromic EBT2 (Poster notice,General)
34.
2015/06
Energy response of the GAFCHROMIC EBT3 in diagnosis range (Poster notice,General)
35.
2015/06
Investigation of presampled MTF using a slit device with slightly wider aperture (Poster notice,General)
36.
2015/06
Evaluation of the eye lens dose according to patient setup errors in pediatric head CT examination (Speech,General)
37.
2015/06
Noise reduction of radiochromic film: median filter processing of subtraction image (Speech,General)
38.
2015/06
Reaction of three UV exposure to gafchromic EBT-2 and EBT-3 (Speech,General)
39.
2015/06
Study of the response of ionization chambers in photon beams for off-axis point dose (Poster notice,General)
40.
2014/09/07
Evaluation of scanner image properties of radiochromic film for measuring effective energy (Poster notice,General)
41.
2014/09/07
Evaluation of dose distribution according to patient setup errors in pediatric head CT examination: a phantom study (Poster notice,General)
42.
2014/09/07
A new simplified practical analysis for measuring the presampled MTF using a "virtual slit" image from an edge image (Poster notice,General)
43.
2013/10/09
Sonographic B-mode imaging findings in acute gangrenous cholecystitis (Speech,General)
44.
2011/10/29
Volume Assessment Accuracy in Real-time Three-dimensional Ultrasound: An Abdominal Phantom Study (Speech,General)
45.
2011/09/14
Evaluation of Two Radiochromic Films for HVL Measurement (Poster notice,General)
46.
2011/09/14
Dose Distribution in Pediatric CT Head Examination: Phantom Study (Poster notice,General)
47.
2011/09/14
Effects of bolus volume on geniohyoid muscle movement during swallowing : Ultrasonographic M-mode study in healthy adults (Poster notice,General)
48.
2011/09/14
Diagnostic Validity of High-Density Barium Sulfate in Gastric Cancer Screening by Record Linkage with the Osaka Cancer Registry -AUC Analyses of Sensitivity and Specificity on Sex and Ages of Subjects- (Poster notice,General)
49.
2011/09/14
Impact of additional mammography, as judged necessary by the radiographer, on breast cancer diagnosis (Poster notice,General)
50.
2010/06/07
Dose Distribution in Pediatric Abdominal CT Examination - Using elliptically-shaped sheet-roll phantom - (Poster notice,General)
51.
2010/03/04
Evaluated of Effective Energy Using Radiochromic Film and Step-Shaped Aluminum Filter (Poster notice,General)
52.
2009/09/07
Half-Value Layer Measurement for Effective Energy, Using Radiochromic Film and Step-Shaped Aluminum Filter (Speech,General)
53.
2009/09/07
Reducing Non-uniformity Error of Radiochromic Film in The Diagnostic Range by Ultraviolet Exposure: Preliminary Study (Speech,General)
54.
2009/09/07
Dose Distribution in Pediatric CT Abdominal Examination: Phantom Study (Speech,General)
55.
2009/09/07
The availability of diffusion-weighted imaging with the fluid-attenuated inversion recovery method (FLAIR-DWI) with a low-performance MR unit in chronic ischemia disease (Poster notice,General)
56.
2009/09/07
High Concentration Barium Sulfate Used in Gastric Cancer Screening -Viscosity Change Dependent on the Volume of Artificial Gastric Juice- (Poster notice,General)
57.
2009/09/07
Do additional x-rays taken by a radiographer during x-ray screening for gastric cancer improve detection? (Speech,General)
58.
2009/03/07
Motionless T2 weighted magnetic resonance liver imaging using functional residual capacity breath-hold (Poster notice,General)
59.
2008/11/23
Measurement of Half-Value Layer for QA and QC: Simple Method Using Radiochromic Film Density (Poster notice,General)
60.
2008/11/23
Dose Distribution in Pediatric CT Head Examination: Phantom Study (Poster notice,General)
61.
2008/11/23
T2 weighted liver Magnetic Resonance imaging using functional residual capacity breath-hold with multi breath-hold (Poster notice,General)
62.
2008/11/23
Study on the measurement of ejection fraction(EF) using left ventriculogram (Poster notice,General)
63.
2008/11/23
Studies on Viscosity, pH and Temperature of High Concentration Barium Sulfate in Mass Screening for Gastric Cancer - Particle size distribution - (Poster notice,General)
64.
2008/03/07
Half-value layer measurement using a radiochromic film for QA and QC (Poster notice,General)
65.
2007/06/03
CT dose in pediatric head examination using a new phantom with radiochromic film (Speech,General)
66.
2006/08
Histogram evaluation of absorbed dose on CT exmination (Poster notice,General)
67.
2006/08
Gafchromic Dosimetry Films for Evaluation of Exposure on CT and IVR by Directional Dependences (Poster notice,General)
68.
2006/08
Data Acquisition Methods for Subtraction Image on Dynamic Liver MR (Poster notice,General)
69.
2006/08
Analysis of liver positions for dynamic liver MRI (Poster notice,General)
70.
2005/11
Helical pitch and exposure dose of CT (Speech,General)
71.
2005/11
Study of Optimal Flip Angle on balanced sequence in MR (Speech,General)
72.
2005/11
Sheet roll phantom with radiochromic film of computed tomography (Speech,General)
Display 5 items
Display all(72)
■
Belonging society
1.
2003/08~
Japan Association of Radiological Technologists
2.
2009/12~
European Society of Radiology
3.
2013/04~
Japanese Society of Radiological Technology
4.
2014/11~
Japanese Society of Radiation Safety Management
5.
2018/04~
Society of Multi-Dimension Dosimetry